Measurement of dissolved total nitrogen in wastewater by UV photooxidation with peroxodisulphate - IMT Mines Alès Accéder directement au contenu
Article Dans Une Revue Analytica Chimica Acta Année : 1999

Measurement of dissolved total nitrogen in wastewater by UV photooxidation with peroxodisulphate

B. Roig
C Gonzalez
  • Fonction : Auteur
O. Thomas
  • Fonction : Auteur

Résumé

A simple, rapid procedure using mild conditions has been developed for total nitrogen determination in water samples (10–700 mg N l−1). Reduced forms of nitrogen are oxidised to nitrate by peroxodisulphate/far-UV photooxidation. The nitrate concentration is measured with UV spectrophotometry

Dates et versions

hal-01662400 , version 1 (13-12-2017)

Identifiants

Citer

B. Roig, C Gonzalez, O. Thomas. Measurement of dissolved total nitrogen in wastewater by UV photooxidation with peroxodisulphate. Analytica Chimica Acta, 1999, 389 (1-3), pp.267 - 274. ⟨10.1016/S0003-2670(99)00212-3⟩. ⟨hal-01662400⟩